Title: S200603 - Site Plan - Hunter Ferrell Logistics Park (City Council District 1). Site Plan for Hunter Ferrell Logistics Park, a development with two warehouse buildings totaling 550,518 sq. ft. on 33.44 acres. Tracts 14.2 and 27, Isreal Jennings Survey, Abstract No. 679, City of Grand Prairie, Dallas County, Texas, zoned Light Industrial, and addressed as 2400 and 2701 W Hunter Ferrell Rd. The applicant is B. Cooper, CHI/Acquisitions, L.P., the owner is Hunter Ferrell Land, L.P., and Pete Lindamood. (On June 22, 2020, the Planning and Zoning Commission tabled this case by a vote of 7-0)
Attachments: 1. Exhibit A - Location Map.pdf, 2. Exhibit B - Site Plan for Building A.pdf, 3. Exhibit C - Site Plan for Building B.pdf, 4. Exhibit D - Building Elevations for Building A.pdf, 5. Exhibit E - Building Elevations for Building B.pdf, 6. Exhibit F - Landscape Plan for Building A.pdf, 7. Exhibit G - Landscape Plan for Building B.pdf

From

Chris Hartmann

 

Title

S200603 - Site Plan - Hunter Ferrell Logistics Park (City Council District 1).  Site Plan for Hunter Ferrell Logistics Park, a development with two warehouse buildings totaling 550,518 sq. ft. on 33.44 acres.  Tracts 14.2 and 27, Isreal Jennings Survey, Abstract No. 679, City of Grand Prairie, Dallas County, Texas, zoned Light Industrial, and addressed as 2400 and 2701 W Hunter Ferrell Rd. The applicant is B. Cooper, CHI/Acquisitions, L.P., the owner is Hunter Ferrell Land, L.P., and Pete Lindamood. (On June 22, 2020, the Planning and Zoning Commission tabled this case by a vote of 7-0)

 

Presenter

Savannah Ware, AICP, Chief City Planner

 

Recommended Action

Table

 

Analysis

SUMMARY:

 

Site Plan for Hunter Ferrell Logistics Park, a development with two warehouse buildings totaling 550,518 sq. ft. on 33.44 acres.  Tracts 14.2 and 27, Isreal Jennings Survey, Abstract No. 679, City of Grand Prairie, Dallas County, Texas, zoned Light Industrial, and addressed as 2400 and 2701 W Hunter Ferrell Rd.

 

PURPOSE OF REQUEST:

 

The applicant intends to construct two warehouse buildings on 33 acres.  Site Plan approval by City Council is required for any project involving industrial use.  Development at this location requires City Council approval of a Site Plan because the property is intended for industrial use.

 

The purpose of site plan approval is to ensure that development meets requirements in the Unified Development Code (UDC), provides adequate circulation, and uses quality site planning techniques.  The UDC identifies criteria for evaluating proposed developments.  Criteria include density and dimensional standards, landscaping and screening requirements, and architectural design for special districts.

ADJACENT LAND USES:

The following table summarizes the zoning designation and existing use for the surrounding properties.

Table 1: Adjacent Zoning and Land Uses

Direction

Zoning

Existing Use

North (Site A)

City of Irving

Mobile Home Park

North (Site B)

Light Industrial; PD-9

Truck Parking, Auto Related Use

South

Light Industrial

Undeveloped, Floodway

West

Light Industrial

Lone Star Park Trailhead, Undeveloped

East

Light Industrial

Auto Related Use, Undeveloped

 

PROPOSED USE CHARACTERISTICS AND FUNCTION:

 

The applicant is proposing two development scenarios: the construction of Building A on 13.2 acres or the construction of Building A and Building B on 33 acres.

 

Building A Site Plan

The 13.2-acre site is accessible by two points on W Hunter Ferrell Rd.  The proposed warehouse building is 252,919 sq. ft. and has a loading dock on the south side of the building with 54 dock doors.  The site includes 160 parking spaces and 60 trailer parking spaces.

 

Building B Site Plan

The 19.82-acre site is accessible from W Hunter Ferrell Rd via a shared drive.  The proposed warehouse building is 166,642 sq. ft. and has a loading dock on the north side of the building with 31 dock doors.  The site includes 159 parking spaces and 50 trailer parking spaces.

 

Site Access and Traffic Impact

The right-of-way for Hunter Ferrell Rd is within the City of Irving.  This means that driveway widths and spacing, median openings, deceleration lanes, and pedestrian/bicycle facilities must be approved by the City of Irving.  The proposed access points do not align with existing median openings; any median modifications must also be approved by the City of Irving.

 

ZONING REQUIREMENTS:

 

Density and Dimensional Requirements

Development is subject to the LI standards in the UDC.  The tables below evaluate the density and dimensional standards of the proposed development.  The proposal meets the density and dimensional requirements with the exception of minimum lot width for Site B.

Table 2A: Site Data Summary for Site A

Standard

Required

Provided

Meets

Min. Lot Area (Sq. Ft.)

15,000

593,127

Yes

Min. Lot Width (Ft.)

100

1,253

Yes

Min. Lot Depth (Ft.)

150

508.97

Yes

Front Setback (Ft.)

25

30

Yes

Side Setback (Ft.)

30

30

Yes

Max. Height (Ft.)

50

46.5

Yes

Max. Floor Area Ratio

1:1

0.44:1

Yes

 

Table 2B: Site Data Summary for Site B

Standard

Required

Provided

Meets

Min. Lot Area (Sq. Ft.)

15,000

863,184

Yes

Min. Lot Width (Ft.)

100

82.16

No

Min. Lot Depth (Ft.)

150

568.83

Yes

Front Setback (Ft.)

25

30

Yes

Side Setback (Ft.)

30

89.5

Yes

Max. Height (Ft.)

50

49

Yes

Max. Floor Area Ratio

1:1

0.44:1

Yes

 

Landscape and Screening

The property is subject to landscape and screening requirements in Article 8 and Appendix X of the UDC.  The proposal substantially complies with landscape and screening requirements.

Table 3A: Landscape & Screening Requirements for Site A

Standard

Required

Provided

Meets

Area (Sq. Ft.)

59,312

98,969

Yes

Trees

131

116

No

Shrubs

1,186

2,241

Yes

Foundation Plantings

Along Primary Facades

Along Primary Facades

Yes

Entrance Plantings

At Building Entrance

At Building Entrance

Yes

 

Table 3B: Landscape & Screening Requirements for Site B

Standard

Required

Provided

Meets

Area (Sq. Ft.)

86,318

450,319

Yes

Trees

183

170

No

Shrubs

1,726

1,775

Yes

Entrance Plantings

At Building Entrance

At Building Entrance

Yes

 

Building Materials and Design

Industrial buildings greater than 50,000 sq. ft. are subject to the requirements in Appendix X of the UDC.  Appendix X requires that primary facades include at least three design elements and secondary facades include at least two design elements.  The proposed building elevations meet the design requirements.

Table 4A: Building Design Elements for Building A

Facade

Type

a.

b.

c.

d.

e.

f.

g.

h.

i.

Total Elements

Meets

North

Primary

x

 

 

 

x

x

 

 

 

3

Yes

South

Secondary

x

 

 

x

 

 

 

 

 

2

Yes

West

Primary

x

 

 

 

x

x

 

 

 

3

Yes

East

Primary

x

 

 

 

x

x

 

 

 

3

Yes

 

Table 4B: Building Design Elements for Building B

Facade

Type

a.

b.

c.

d.

e.

f.

g.

h.

i.

Total Elements

Meets

North

Primary

x

 

 

 

x

x

 

 

 

3

Yes

South

Secondary

x

 

 

x

 

 

 

 

 

2

Yes

West

Primary

x

 

 

 

x

x

 

 

 

3

Yes

East

Primary

x

 

 

 

x

x

 

 

 

3

Yes

 

Table 4C: Summary of Building Design Elements

Letter

Primary Facades Element

Secondary Facades Element

a.

Masonry Accents

Masonry Accent

b.

Glass - 15%

Cornice Projection

c.

Awning

Windows - 30%

d.

Cornice Projection

Articulation

e.

Articulation

 

f.

Accent Lighting

 

g.

Colonnade

 

h.

Wing Wall

 

i.

Windows - 30%

 

 

VARIANCES:

 

City Council may approve variances to Appendix X if the applicant demonstrates that the proposal meets the intent of the ordinance and that the alternative design or measure provides an equal or greater level of quality and standard of development as mandated by the regulations.  As a part of this Site Plan, the applicant is requesting the variances listed below.

1.                     Truck Docks Location for Building B - Truck docks are prohibited along any primary facade.

2.                     Tree Preservation Requirements - Appendix X requires that developers submit a tree survey and preserves a minimum of 30% of the total existing caliper inches.  The applicant has not submitted a tree survey.

3.                     Minimum Lot Width for Site B - Site B does not meet the minimum required lot width.

 

RECOMMENDATION:

 

The Development Review Committee (DRC) recommends approval with the following conditions:

 

1.                     The applicant shall coordinate with the Parks Department to connect the proposed walking trails to the existing trail west of the property.  The applicant shall construct this connection in conjunction with the proposed trail and activation feature.

 

2.                     The applicant shall provide an additional row of street trees closer to Hunter Ferrell Rd to create shade along the existing trail.  These trees will count towards the required number of trees.  The proposed number of trees is 28 less than what is required.  The applicant shall coordinate with the Parks Department and City of Irving on the placement of trees along the trail.