Legislation Details

File #: 20-10362    Version: 1 Name: S200902 - Site Plan - West Oakdale Industrial III (City Council District 1)
Type: Agenda Item Status: Passed
File created: 9/4/2020 In control: Planning and Zoning Commission
On agenda: 10/13/2020 Final action: 10/13/2020
Title: S200902 - Site Plan - West Oakdale Industrial III (City Council District 1). Site Plan for a 2-story, 335,687 sq. ft. Office-Showroom/Warehouse facility on one lot. 19.30 acres out of the James McLaughlin Survey, Abstract 848, City of Grand Prairie, Dallas County, Texas, zoned Planned Development-39 (PD-39) District, generally located south of E. Oakdale Road and 1,650 ft. west of N. Belt Line Road. (On September 14, 2020, the Planning and Zoning Commission recommended approval of this request by a vote of 9-0).
Attachments: 1. Exhibit A Locator Map S200902, 2. Exhibit B SP S200902, 3. Exhibit C LP S200902, 4. Exhibit D Tree Suv S200902, 5. Exhibit E Elev S200902, 6. PZ Draft Minutes 09-14-2020.pdf

From

Monica Espinoza                     

 

Title

S200902 - Site Plan - West Oakdale Industrial III (City Council District 1).  Site Plan for a 2-story, 335,687 sq. ft. Office-Showroom/Warehouse facility on one lot. 19.30 acres out of the James McLaughlin Survey, Abstract 848, City of Grand Prairie, Dallas County, Texas, zoned Planned Development-39 (PD-39) District, generally located south of E. Oakdale Road and 1,650 ft. west of N. Belt Line Road. (On September 14, 2020, the Planning and Zoning Commission recommended approval of this request by a vote of 9-0).

 

Presenter

Charles Lee, AICP, CBO, Senior Planner

 

Recommended Action

Approve

 

Analysis

SUMMARY:

Site Plan request to authorize construction an office/warehouse building on 19.30 acres.   The proposed development is situated in the James McLaughlin Survey, Abstract No. 848, City of Grand Prairie, Dallas County, Texas, generally located south of E. Oakdale Road approximately 1,650 feet west of N. Belt Line Road.  The property is zoned Planned Development 39 (PD-39) District.

 

PURPOSE OF REQUEST:

 

The applicant intends to construct a 335,687 sq. ft. office/warehouse building on 19.30 acres.  The proposed site consists of multiple undeveloped tracts that would be subsequently platted into one property. Site Plan approval by City Council is required for any project involving industrial uses with buildings exceeding 50,000 square feet.

 

The purpose of site plan approval is to ensure that development meets requirements in the Unified Development Code (UDC), provides adequate circulation, and uses quality site planning techniques.  The UDC identifies criteria for evaluating proposed developments.  Criteria include density and dimensional standards, landscaping and screening requirements, and architectural design for special districts.

Appendix X: Industrial Development Standards of the UDC addresses potential adverse environmental, visual, and truck traffic associated with large warehouses, outside storage, distribution-logistical related developments exceeding five acres in size.

ADJACENT LAND USES:

The following table summarizes the zoning designation and existing use for the surrounding properties.

Table 1: Adjacent Zoning and Land Uses

Direction

Zoning

Existing Use

North

LI

Undeveloped

South

PD-39

Undeveloped

West

PD-39

Undeveloped

East

PD-39

Undeveloped (Open Space)

 

PROPOSED USE CHARACTERISTICS AND FUNCTION:

 

The proposal includes one side-loaded office/warehouse-building.  The building is speculative and will be developed without specific tenants.  The site will be accessible from two commercial drives off W. Oakdale Road and includes a fire lane and access easement that loops around the facility.  The site includes 76 overhead dock doors and 84 tractor trailer parking spaces.

 

ZONING REQUIREMENTS:

 

Density and Dimensional Requirements

Development is subject to the LI and Appendix X Industrial Development Standards in the UDC.  The table below evaluates the density and dimensional standards of the proposed development.  The proposal meets the density and dimensional requirements.

Table 2: Site Data Summary

Standard

Required

Provided

Meets

Min. Lot Area (Sq. Ft.)

15,000

840,761

Yes

Min. Lot Width (Ft.)

100

820

Yes

Min. Lot Depth (Ft.)

150

1,457

Yes

Front Setback (Ft.)

25

100

Yes

Side Setback (Ft.)

30

200

Yes

Max. Height (Ft.)

50

47.5

Yes

Max. Floor Area Ratio

1:1

0.44:1

Yes

 

Landscape and Screening

The property is subject to landscape and screening requirements in Article 8 and Appendix X of the UDC.  The table below summarizes the requirements.  The site exceeds the minimum landscape area, number of trees, and number of shrubs and screening requirements.

Table 3: Landscape & Screening Requirements

Standard

Required

Provided

Meets

Area (Sq. Ft.)

84,076

125,320

Yes

Trees

168

168

Yes

Parking Lot Trees

17

35

Yes

Shrubs

1,682

1,758

Yes

Foundation Plantings

Along Primary Facades

Provided Plantings

Yes

Entrance Plantings

At Building Entrance

Provided Plantings

Yes

Truck Screening

Wing Wall

Wing Walls

Yes

 

The site includes the required activation feature with 1.09 acres of open space, 978 linear ft. of walking trails, a seating area, and a 6,832 sq. ft. garden.

Building Materials and Design

Industrial buildings greater than 50,000 sq. ft. are subject to the requirements in Appendix X of the UDC. Appendix X requires that primary facades include at least three design elements and secondary facades include at least two design elements.  The tables below evaluate the design elements for each building.  The proposed building elevations meet Appendix X requirements.

The building exterior consists of textured concrete tilt-wall panels.  The north facade elements include 15% glazing, building articulation, and accent lighting. 

Table 4: Building Design Elements

Facade

Type

a.

b.

c.

d.

e.

f.

g.

h.

i.

Total Elements

Meets

North

Primary

 

Y

 

 

Y

Y

 

 

 

        3

    Yes

South

Secondary

Y

 

 

Y

 

 

 

 

 

        2

    Yes

West

Secondary

Y

 

 

Y

 

 

 

 

 

        2

    Yes

East

Secondary

Y

 

 

Y

 

 

 

 

 

        2

    Yes

 

VARIANCES:

The applicant is not requesting any variances.

 

RECOMMENDATION: